TM 10--3510--221--24
0091 00--1/2 blank
WATER IN AIR LINES
0091 00
THIS WORK PACKAGE COVERS:
Troubleshooting Air Compressor Does Not Come On Fault
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
Power must be removed at main control
Multimeter (Item 2, WP 0272 00)
enclosure (WP 0010 00).
1. Position SW2 and SW1 to OFF.
2. Check for a clogged element in coalescing filter (TM 10--3510--221--10).
Is filter element clogged?
YES Replace filter element.
NO Go to step 3.
3. Fill bowl from coalescing filter with water to check automatic drain operation.
Does water drain when bowl is filled?
YES Go to step 4.
NO Replace coalescing filter (WP 0200 00).
4. Open door on main control enclosure.
5. Check wire connections between dehydrator and circuit breaker CB8 and between dehydrator terminal
board TB1.
Are wire connections OK?
YES Replace dehydrator (WP 0201 00).
NO Repair as necessary.
END OF WORK PACKAGE