TM 10--3510--221--24
0135 00--1
INLET/OUTLET AIR TEMPERATURE
SENSOR REPLACEMENT
0135 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tape, Anti--Seizing (Item 10, WP 0271 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
LADS power shut off at main control
enclosure (WP 0112 00).
REMOVAL
1. Disconnect electrical connector (1) from temperature sensor (2).
2. Loosen nut (3) then remove temperature sensor (2) from fitting (4).
3. Measure and record distance from tip of temperature sensor (2) to lower ferrule (5).
4. Unthread fitting (4) from inlet duct (6).
5. Clean anti--seizing tape from threads of fitting (4).
1