TM 10--3510--221--24
0132 00--3/4 blank
OUTLET DAMPER AIR CYLINDER
REPLACEMENT -- Continued
0132 00
INSTALLATION
1. Apply anti--seizing tape to threads of flow control valves (16).
2. Install flow control valves (16) into new air cylinder (2).
3. Thread thread jam nut (15) and rod adapter (14) on to piston (13).
4. Adjust position of rod adapter (14) as follows:
a. Extend piston (13).
b. Thread rod adapter (14) in or out to achieve previously recorded dimension.
c. Tighten jam nut (15).
5. Insert air cylinder (2) between mounting bracket (12) and link arm (9).
6. Install clevis pin (11) to secure air cylinder (2) to mounting bracket (12).
7. Install hair pin (10) to secure clevis pin (11).
8. Install clevis pin (8) to secure air cylinder (2) to link arm (9).
9. Install hair pin (7) to secure clevis pin (8).
NOTE
Step 10 applies to drum B only.
10. Install protective cover (5) on top off outlet duct (6) then secure with six screws (3) and lock washers (4).
11. Connect air lines (1) to air cylinder (2) as tagged.
12. Adjust flow control valves (WP 0133 00).
END OF WORK PACKAGE