TM 10--3510--221--24
0135 00--2
INLET/OUTLET AIR TEMPERATURE
SENSOR REPLACEMENT -- Continued
0135 00
INSTALLATION
1. Connect electrical connector (1) to temperature sensor (2).
2. Access examine inputs function using maintenance menu (WP 0010 00), then observe and record temperature
reading for TE100.
3. Access temperature sensor calibration function using maintenance menu (WP 0010 00), then set output of
temperature sensor TE101 (inlet) or TE102 (outlet) to same temperature reading as recorded for TE100.
4. Slide new nut (3), upper ferrule (7) and lower ferrule (5) onto new temperature sensor (2).
5. Insert temperature sensor (2) into fitting (4) at previously recorded dimension.
6. Tighten nut (3) onto fitting (4) to swage lower ferrule (5) on temperature sensor (2).
7. Loosen nut (3) and remove temperature sensor (2) from fitting (4).
8. Apply anti--seizing tape to threads of fitting (4).
9. Thread fitting (4) into inlet duct (6).
10. Insert temperature sensor (2) into fitting (4) then tighten nut (3).
11. Perform a test laundry cycle (TM 10--3510--221--10). Verify normal drying operation.
END OF WORK PACKAGE