TM 10--3510--221--24
0134 00--1/2 blank
AMBIENT AIR TEMPERATURE SENSOR
REPLACEMENT
0134 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tape, Anti--Seizing (Item 10, WP 0271 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
LADS power shut off at main control
enclosure (WP 0112 00).
REMOVAL
1. Disconnect electrical connector (1) from temperature sensor (2).
2. Loosen nut (3) then remove temperature sensor (2) from fitting (4).
4
6
5
3
1
2
INSTALLATION
1. Slide new nut (3), upper ferrule (5) and lower ferrule (6) onto new temperature sensor (2).
2. Insert temperature sensor (2) into fitting (4) then tighten nut (3).
3. Connect electrical connector (1) to temperature sensor (2).
4. Access examine inputs function using maintenance menu (WP 0010 00), then observe and record temperature
reading for TE101.
5. Access temperature sensor calibration function using maintenance menu (WP 0010 00), then set output of
temperature sensor TE100 to same temperature reading as recorded for TE101.
END OF WORK PACKAGE