TM 10--3510--221--24
0153 00--3/4 blank
OUTLET B WATER CONTROL VALVE
REPLACEMENT -- Continued
0153 00
INSTALLATION
1. Apply anti--seizing tape to threads of elbows (4).
2. Thread two elbows (4) into new control valve (5).
3. Apply pipe thread sealant to threads of outlet B manifold (2) and adapter (11).
4. Thread adapter (11) into control valve (5).
5. Thread control valve (5) onto outlet B manifold (2) and orient as shown.
6. Install new gaskets (10) onto outlet B manifold (2).
7. Position outlet B manifold (2) under water tanks (9).
8. Attach outlet B manifold (2) to water tanks (9) as follows:
a. Mate each adapter (11) to fitting on water tanks (9) ensuring gasket (10) remains in place.
b. Install clamp (8).
c. Repeat steps a and b at other two connection points.
9. Connect hose (7) to outlet B manifold (2) tighten clamp (6).
10. Connect tubes (3) to elbows (4) on three control valves (5) as tagged.
11. Attach tubes (3) to outlet B manifold with tiedown straps.
12. Install cap (1) onto outlet B manifold (2).
13. Install inlet A manifold (WP 0152 00).
14. Install inlet B manifold (WP 0151 00).
15. Perform a FILL TANKS, HEAT TANKS, and test laundry cycle operation (TM 10--3510--221--10). While water is
circulating visually check for water leaks.
END OF WORK PACKAGE