TM 10--3510--221--24
0188 00--1/2 blank
PURGE CARD REPLACEMENT
0188 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
LADS power be shut off at main control
enclosure (WP 0112 00).
REMOVAL
1. Loosen four latches (1), then open door (2) on heater enclosure (3).
2. Remove display module (4) from flame programmer (5).
3. Remove pull purge card (6) out of flame programmer (5).
5
4
6
1
3
2
INSTALLATION
1. Insert new purge card (6) into flame programmer (5).
2. Install display module (4) onto flame programmer (5).
3. Close door (2) and secure to heater enclosure (3) by tightening four latches (1).
4. Use maintenance menu to test heating system (WP 0010 00).
END OF WORK PACKAGE