TM 10--3510--221--24
0201 00--3/4 blank
DEHYDRATOR REPLACEMENT -- Continued
0201 00
INSTALLATION
1. Apply anti--seizing tape to threads of elbow (17) and connector (19).
2. Thread connector (19) into new dehydrator (10).
3. Thread elbow (17) into dehydrator (10).
4. Position dehydrator (10) on frame (22), then secure with four screws (20), and flat washers (21).
5. Connect tube (18) to connector (19).
6. Connect tube (16) to elbow (17).
7. Insert power cord (9) into outlet box (8)
8. Connect power cord (9) as tagged.
9. Tighten nut (11) on cord grip (12).
10. Install cover (6) and gasket (7) onto outlet box (8), then secure with two screws (5).
11. Install tiedown straps (13) to secure power cord (9) to tubing (14) and air compressor (15).
12. Use maintenance menu to test air system (WP 0010 00). After air system is pressurized audibly check for air
leaks.
13. Close access door (2) and secure by engaging two latches (1).
END OF WORK PACKAGE