TM 10--3510--221--24
0200 00--2
COALESCING FILTER REPLACEMENT -- Continued
0200 00
4
3
7
8
10
9
6
12
11
5
INSTALLATION
1. Apply anti--seizing tape to threads of elbow (6) and nipple (12).
2. Thread nipple (12) into inlet port of new coalescing filter (11).
3. Thread elbow (6) into coalescing filter (11).
4. Position coalescing filter (11) on bracket (10), then secure with pipe clamp (9).
5. Connect tube (7) to fitting (8).
6. Connect tube (5) to elbow (6).
7. Use maintenance menu to test air system (WP 0010 00). After air system is pressurized audibly check for air
leaks.
8. Close access door (2) and secure by engaging two latches (1).
END OF WORK PACKAGE