TM 10--3510--221--24
0216 00--1
CARD CAGE REPLACEMENT
0216 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tags (Item 9, WP 0271 00)
Washer, Lock (Item 18, WP 0275 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
LADS power must be shut off and door opened at
main control enclosure (WP 0112 00).
REMOVAL
1. Remove digital I/O PCB (WP 0212 00).
2. Remove optically isolated PCB (WP 0213 00).
3. Remove analog to digital converter PCB (WP 0214 00).
4. Remove CPU PCB (WP 0215 00).
5. ESD. Remove four screws (1), lock washers (2) and flat washers (3), then lift card cage (4) up to access
bottom wire connections.
6. ESD. Loosen screw terminals (5) then tag and disconnect wires from connector (6).
7. ESD. Loosen screw terminals (7) then tag and disconnect wires from connector (8).