TM 10--3510--221--24
0226 00--1
+12 VDC POWER SUPPLY REPLACEMENT
0226 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tags (Item 9, WP 0271 00)
Washer, Lock (Item 18, WP 0275 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
LADS power must be shut off and door opened at
main control enclosure (WP 0112 00).
REMOVAL
1. Tag and disconnect wires from power supply (1).
2. Remove four screws (2) and lock washers (3), then remove power supply (1) from subpanel (4).
8
7
6
5
2
3
1
4