TM 10--3510--221--24
0227 00--1
PERISTALTIC PUMP REPLACEMENT
0227 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Rag, Wiping (Item 4, WP 0271 00)
Tags (Item 9, WP 0271 00)
Tubing, Silicone, 1/4 ID (Item 1, WP 0273 00)
Strap, Tiedown (Item 10, WP 0275 00)
Washer, Lock (Item 19, WP 0275 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
LADS power must be shut off and door opened at
main control enclosure (WP 0112 00).
REMOVAL
WARNING
1. Remove cover (1) from wire duct (2).
2. Tag and disconnect lead wires (3) at wire duct (2).
3. Pull lead wires (3) out of wire wire duct (2) and through panel (4).
4. Remove four screws (5) then remove cover (6) from peristaltic pump (7).
5. Remove tube (8) from peristaltic pump (7). Measure and record length of tube (8).
6. Remove four screws (9), lock washers (10), and flat washers (11), then remove peristaltic pump (7) from
standoffs (12).
7. Slide clamp (13) off of tube (8) then disconnect tube from tee (14).
8. Loosen clamp (15), then disconnect tube (8) from elbow (16).
9. Remove clamps (13 and 15) from tube (8).
10. Wipe any residual anti--foam or detergent out of main control enclosure (17) with a clean rag.