TM 10--3510--221--24
0245 00--3/4 blank
INVERTER DRIVE REPLACEMENT -- Continued
0245 00
INSTALLATION
1. Loosen two captive screws (4), then remove cover (5) from new inverter drive (6).
2. Position inverter drive (6) into inverter enclosure (3), then secure with four nuts (15) and flat washers (16).
3. Insert control cable (12) input wiring (13), and output wiring (14) into inverter drive (6).
4. Connect wires to control bus (9), input bus (10), output bus (8) and ground lug (11) as tagged.
5. Install cover (5) onto inverter drive (6), then secure with two captive screws (4).
6. Place door (2) onto inverter enclosure (3), then secure by tightening eleven latches (1).
7. Using maintenance menu (WP 0010 00) verify correct operation as follows:
a. For inverter drive K100A or B test drum motor M100A or B rotation at all speeds and directions.
b. For inverter drive K104 test dryer blower motor M104A and B operation.
c. For inverter drive K200 test still condenser fan M200 and thermal fluid pump M300 operation. Also test
heating system.
END OF WORK PACKAGE