TM 10--3510--221--24
0246 00--1
TUBE AXIAL FAN REPLACEMENT
0246 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Washer, Lock (Item 17, WP 0275 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
LADS power shut off at main control
enclosure (WP 0112 00).
REMOVAL
1. Loosen eleven latches (1), then lift door (2) off of inverter enclosure (3).
2. Remove seven screws (4) and lock washers (5), then remove outlet duct (6) and gasket (7) from inverter
enclosure (3).
3. Disconnect plug & cord (8) from fan (9).
4. Remove four screws (10), flat washers (11), and nuts (12), then remove fan (9), spacer (13), and two finger
guards (14) from inverter enclosure (3).