TM 10--3510--221--24
0246 00--2
TUBE AXIAL FAN REPLACEMENT -- Continued
0246 00
14
1211
9
8
13
10
14
INSTALLATION
1. Position new fan (9), spacer (13), and two finger guards (14) on inverter enclosure (3), then secure with four
screws (10), flat washers (11), and nuts (12).
2. Connect plug & cord (8) to fan (9).
3. Position outlet duct (6) and gasket (7) on inverter enclosure (3), then secure with seven screws (4) and lock
washers (5).
4. Place door (2) onto inverter enclosure (3), then secure by tightening eleven latches (1).
5. Position MAIN DISCONNECT switch (WP 0009 00, Figure 1, 1) to ON. Verify fan is operating.
END OF WORK PACKAGE