TM 10--3510--221--24
0010 00--1
LAUNDRY ADVANCED SYSTEM
MAINTENANCE MENU OPERATION
0010 00
MAINTENANCE MENU OPERATION
A. ACCESSING MAINTENANCE MENU
NOTE
Prior to using maintenance menu control system power must be removed and the
processor restarted. When leaving maintenance menu normal system operation can be
started without powering down.
1. Cycle CONTROL POWER switch (SW2) to OFF then back to ON.
2. Monitor display at operator panel A, it should read:
TESTING CONTROL SYSTEM
WAIT
then
PRESS TO START
3. Press MENU SELECTION switches (PBS2A, 3A, and 4A) sequentially.
4. Monitor display, it should read:
EXAMINE INPUTS
MAINTENANCE MENU
CONTROL OUTPUTS
OTHER OPTIONS
RETURN
5. Press appropriate MENU SELECTION switch as follows:
a. Select EXAMINE INPUTS to monitor level, pressure, or temperature parameters or status of discrete
switching devices. Proceed to step B.
b. Select CONTROL OUTPUTS to check operation of systems or individual components such as motors and
valves. Proceed to step C.
c. Select OTHER OPTIONS to review perform calibrations. Proceed to step D.
d. Select RETURN to exit maintenance men and return to normal operation.