TM 10-3510-222-24
2-69. FAN AND MOTOR.
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools
Equipment Condition
General Mechanics Tool Kit (App B, Item 1)
Dryer shut down (TM 10-3510-222-10)
Blower removed (Para 2-50)
Rotary Pump removed (Para 2-53)
a.
REMOVAL
(1)
Remove eight screws (1) and lockwashers (2).
(2)
Remove fan housing (3).
(3)
Loosen setscrew (4) and remove collar (5).
(4)
Loosen setscrew (6) and remove fan (7) and key (8).
(5)
Remove four screws (10) and lockwashers (11).
(6)
Remove motor (12) from adapter plate (9).
b.
INSTALLATION
(1)
Position adapter plate (9) on motor (12) and install four lockwashers (11) and screws (10).
NOTE
A gap of 1/4" between adapters and fan is required.
(2)
Position key (8) on motor (12) and install fan (7). Tighten setscrew (6).
(3)
Install collar (5) and secure with setscrew (4).
(4)
Position fan housing (3) on adapter plate (9) and install eight screws (1) and lockwashers (2).
(5)
Install blower (Para 2-50).
(6)
Install rotary pump (Para 2-53).
2-159