TM 10-3510-222-24
3-38. POWER PANEL- continued
NOTE
Wire numbers are stamped on each electrical wire This information, in conjunction with data on
FO-1 Laundry Unit Interconnect Wiring Diagram, may be used to connect wires if tags are lost or
illegible
(k) Connect electrical wiring to connector (30).
(l)
Position circuit breaker bracket (5) on power panel (31) and install four screws (4).
(m) Position right and left brackets (3), top and bottom brackets (2) and install four screws (1).
(n) Close power panel door (31).
c. INSTALLATION
(1) Install two bolts (19), flat washers (20) and nuts (18).
(2) Position power panel (31) on washer control stand and install two flat washers (17), lockwashers (16) and nuts (15).
(3) Install sealing washer (13), conduit (14) and nut (12).
(4) Install sealing washer (10), flexible conduit (11) and nut (9).
(5) Install sealing washer (7), flexible conduit (8) and nut (6).
NOTE
Wire numbers are stamped on each electrical wire. This information, in conjunction with data on
FO-1 Laundry Unit Interconnect Wiring Diagram, may be used to connect wires if tags are lost or
illegible
(6)
Connect electrical wiring to circuit breakers (25 and 27) as tagged.
(7)
Position circuit breaker bracket (5) on power panel (31) and install four screws (4).
(8)
Position right and left brackets (3), top and bottom brackets (2) on power panel (31) and install four screws (1).
(9)
Close power panel door (21).
(10) Install enclosure box (Para 3-37).
3-92