TM 10-3510-222-24
3-64. TIMER.
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools
General Mechanics Tool Kit (App B, Item 1)
Material/Parts
Tags (App D, Item 4)
Equipment Condition
Laundry Unit shut down (TM 10-3510-222-10).
Shield removed (Para 2-71)
General Safety Instructions
WARNING
Voltage in this equipment is high enough
to cause serious injury or death. Do not
perform this task with power on.
a.
REMOVAL
(1)
Remove three screws (1) and remove timer (2) from box (10).
(2)
Tag and disconnect wires.
(3)
Remove conduit nuts (3 and 4).
(4)
Remove four nuts (5), lockwashers (6) and screws (7).
(5)
Remove nipple (8), four spacers (9) and box (10).
b.
INSTALLATION
(1)
If removed, install box (10) as follows:
(a)
Position nipple (8), four spacers (9) and box (10) on unit and secure with four nuts (5),
lockwashers (6) and screws (7).
(b)
Install two conduit nuts (3 and 4).
NOTE
Wire numbers are stamped on each electrical wire. This information, in conjunction with data on
FO-4 Dryer Wiring Diagram, may be used to connect wires if tags are lost or illegible.
(2)
Connect wires as follows:
Numbered wires
Timer wires
32
Red
35
Green
38
Yellow
31
Brown
3-148