3-65. UV SCANNER AND TERMINAL BOX.
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools
General Mechanics Tool Kit (App B, Item 1)
Materials/Parts
Tags (App D, Item 4)
Equipment Condition
Laundry Unit shut down (TM 10-3510-222-10)
Door open (Para 2-71)
General Safety Instructions
WARNING
Voltage in this equipment is high enough
to cause serious injury or death. Do not
perform this task with power on.
a.
REMOVAL
(1)
Unscrew captive screw (1) and remove cover (2).
(2)
Unscrew two screws (3) and remove UV scanner (4) from terminal box (8).
(3)
Tag and disconnect all wires from terminal board (9).
(4)
Remove plug-in program board (5). Retain for installation on replacement UV scanner (4).
(5)
Remove four screws (6), lockwashers (7) and terminal box (8).
b.
INSTALLATION
(1)
Position terminal box (8) on dryer and secure with four screws (6) and lockwashers (7).
NOTE
Wire numbers are stamped on each electrical wire. This information, in conjunction with data on
FO-4 Dryer Wiring Diagram, may be used to connect wires if tags are lost or illegible.
(2)
Connect wires to terminal board (9) as tagged.
(3)
Position UV scanner (4) in front of terminal box (8) and align screws (3) with mounting holes on box.
Tighten screws (3).
(4)
Install plug-in program board (5) on UV scanner (4).
(5)
Position cover (2) on top of UV scanner (4) and secure with captive screw (1).
(6)
Close door (Para 2-71).
3-150