TM 10-3510-223-13&P
0029 00
0029 00-3
PROCEDURE 2 COVERS:
Internal Component Power Loss
INITIAL SETUP:
CSSL set up but not in operation
Maintenance Level
Materials/Parts
Direct Support
None
PERFORM TROUBLESHOOTING
PROCEDURES #1
IS POWER AVAILABLE AT THE COMPONENT
CIRCUIT BREAKER ?
USING A MULTIMETER SET TO MEASURE
AC VOLTAGE, CHECK THE AVAILABILITY OF
POWER AT THE COMPONENT BREAKER.
(REFER TO WORK PACKAGE 0031 00)
SWITCH BREAKER TO ON POSITION
AND OPERATE COMPONENT.
(REFER TO WORK PACKAGE 0005 00)
ARE COMPONENT OPERATING CONTROLS
PROPERLY SET OR ADJUSTED ?
SET OR ADJUST COMPONENT
CONTROLS AS NECESSARY FOR
OPERATION.
(REFER TO WORK PACKAGE 0005 00)
CHECK POWER SUPPLY WIRING TO THE
COMPONENT FOR PHYSICAL DAMAGE.
REPLACE WIRING AS NECESSARY.
REPLACE A DEFECTIVE COMPONENT AS
DESCRIBED IN WORK PACKAGES 0031 00
THROUGH 0043 00
NO
YES
IS POWER AVAILABLE AT MAIN BREAKER ?
USING A MULTIMETER SET TO MEASURE
AC VOLTAGE, CHECK THE AVAILABILITY OF
POWER AT THE MAIN BREAKER.
(REFER TO WORK PACKAGE 0031 00)
YES
YES
NO
NO