TM 10-3510-223-13&P
0033 00
CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) MODEL A
DIRECT SUPPORT MAINTENANCE
0033 00-1
FLUORESCENT LIGHTS
THIS SECTION COVERS:
Test, Replace
INITIAL SETUP
CSSL not in operation
Materials/Parts
Maintenance Level
Retainer clips (WP 0072, Table 1, Item 19)
Direct Support
Tape, elec. Ins. (WP 0072, Table 1, Item 15)
Tools and Special Tools
Tags, marking (WP 0072, Table 1, Item 10)
Tool Kit, Elec. Equipment (WP 0045 Table 2 Item 3)
Light, Fluorescent (WP 0072, Table 1, Item 2)
WARNING
This equipment operates at High Voltages. Use extreme caution.
Observe all warnings, and follow all safety procedures. Touching a
live wire can cause serious injury or death.
TEST
Isolate electrical malfunction of an interior fluorescent light as described in Procedure 2 of Direct Support
Troubleshooting Procedures contained in work package 0029.
REPLACE
Replace an interior fluorescent light as described below. This procedure requires two persons.
NOTE
CSSL interior fluorescent light fixtures are of various manufacture and
may differ slightly in the method of installation.
Remove
Place Circuit Breaker #1 on Circuit Breaker Panel #1 to OFF. Remove dust cover (1) from light fixture (2).
Pull clips from light bulb sockets (3) and turn bulbs (4) to remove them. If light bulbs must be replaced,
remove insulators (5 from bulbs.
Loosen inner cover retainer (6) and remove cover (7). Remove ground wire (8) from fixture. Disconnect
black and white wires (9). (Wire connectors may be screw caps, or crimp type, and vary with different light
fixtures)
Loosen hex retainer nut (10) at conduit (11) and pull conduit from fixture. With second person supporting
the lightfixture, remove hex nuts (12) and washers from the ceiling bracket studs (13).