TM 10-3510-223-13&P
0039 00
CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) MODEL A
DIRECT SUPPORT MAINTENANCE
0039 00-1
WASTEWATER ALARM
THIS SECTION COVERS:
Test, Replace
INITIAL SETUP
CSSL not in operation
Maintenance Level
Direct Support
Materials/Parts
Tools and Special Tools
Wiping Rags (WP 0072, Table 1, Item 1)
Tool Kit, Electrical Equipment
(WP 0045 Table 2 Item3)
Tape, elec. Ins. (WP 0072 00 Table 1, Item 15)
Tags (WP 0072 00 Table 1, Item 10)
WARNING
This equipment operates at High Voltages. Use extreme caution.
Touching a live wire can cause serious injury or death. The procedures
in this work package can be performed only by qualified civilian or
military personnel in MOS 51R, 52C, 52D, or 52G.
TEST
Isolate electrical malfunction of the wastewater alarm as described in Procedure 2 of the Direct Support
Troubleshooting Procedures contained in work package 0029.
REPLACE
Before replacing the wastewater alarm, ensure main breaker on distribution panel #1 is set to OFF. A
flashlight (obtain from footlocker) will be required for this procedure.
Remove
Open wastewater alarm box (1), disconnect and tag the electrical supply wires from the S1 terminal strip
(Refer to panel layout illustration on page 0038 00-4 and the commercial literature furnished with pump
control panel) Loosen conduit connector (2) to disconnect conduit (3) from the alarm box. Remove the
four hex nuts and washers (4) that hold the alarm box (1) to the wall mounts (5). Remove the box from
the wall mounts and conduit.