TM 10-3510-223-13&P 0005 00
0005 00-43
WARNING
Avoid spillage of wastewater during preparation for movement. Drain
wastewater hoses into an approved disposal facility. Keep wastewater
hoses separate from freshwater hoses.
After the wastewater pump (1) has stopped running, shut off the pump (Circuit Breaker #16, Panel #1).
Drain the remaining water from the interior wastewater tank (2) by removing the drain plug (3) with an
adjustable wrench. Reinstall the plug after tank has drained.
When a municipal disposal system was connected:
Disconnect the 2 wastewater hose (4) from the wastewater panel (5) on the curbside of the container,
and drain it into the disposal connection. Disconnect 2 wastewater hose (4) from wastewater disposal
point. Coil the hose and set it aside. Install dust cap (6) on panel (5).
When a 3,000 Gallon wastewater collection tank was connected:
Disconnect the 2 wastewater hose (4) from the wastewater panel (5) on the curbside of the container.
While holding the end of the hose (4) above the water level in the 3,000 Gallon wastewater tank (7), place
the end of the hose into the wastewater tank (7). Install dust cap (6) on panel (5).
WARNING
The 3,000 Gallon water tank is heavy. To avoid injuries, four persons are
required to prepare the CSSL for shipment.
Empty the 3,000 Gallon wastewater tank (7) in accordance with TM 5-5430-227-12&P. Remove the 2
wastewater hose (4) from the wastewater tank. Drain the hose, coil, and set aside.
Disassemble and place 3,000 Gallon wastewater tank (7) into its bag in accordance with TM 5-5430-227-
12&P.