WARNING
This procedure requires four personnel to lower the fan from atop the
container. Personnel in the 5th percentile size group may require a step
aide during this procedure.
Unplug exhaust fan power cord (1) from ceiling raceway outlet (2).
Inside the container, remove captive tiedown knobs (3) securing the ventilation fan (4). (Switch interior
lights ON with LIGHTS switch on the roadside raceway, if necessary).
Using the folding steps (5) located on the outside of the rear end roadside wall of the container, have two
personnel gain access to the top of the container.
From top of container, remove the ventilation fan (4) from its mount (6) and lower it over the roadside of
the container to two persons on the ground.
Retrieve exhaust fan panel (7) from behind washer/dryer #1 and hand it to personnel atop container.
Place panel over ventilation fan mount (6) and secure panel with captive tiedown knobs (3) from inside
the container.
PREPARE TEMPER WITH MODIFIED END SECTION FOR SHIPMENT
2
1
3
7
6
4
5