TM 10-3510-224-13&P
0033 00
DIRECT SUPPORT MAINTENANCE
CONTAINERIZED SELF SERVICE LAUNDRY (CSSL)
NSN 3510-01-485-0457
FRESHWATER PUMP AND INTERNAL FRESHWATER LINE
REPLACE
INITIAL SETUP:
Equipment Condition
CSSL not in operation
Materials/Parts
Wiping Rags (WP 0070 00, Table 1, Item 1)
Solder, Lead-Free (WP 0070, Table 1, Item 4)
Tape, Antiseize (WP 0070, Table 1, Item 3)
Tools and Special Tools
Tool Kit, Org. Maintenance, Common No.1
(WP 0042, Table 2, Item 2)
Pipe Wrench 18 (WP 0042, Table 2, Item 4)
Pipe Wrench 10 (WP 0042, Table 2, Item 5)
Tube Cutter. (WP 0042, Table 2, Item 6)
Personnel Required
Two
WARNING
This equipment operates at high voltages. Use extreme caution during test
procedure. Touching a live wire can cause serious injury or death. Only MOS 51R,
52C, 52D, 52G or a qualified civilian must perform this procedure.
REPLACE
1. Before replacing the freshwater pump (1) disconnect the 2 freshwater hose from the freshwater input panel.
2. Connect a garden hose to the fitting at the end of the main supply line (2) (located behind washer/dryer #6) and
open the ball valve (3).
3. Remove the pressure switch (4) as described in work package 0034 00.
4. After removing the pressure switch, disconnect the 1 hex union fitting (5) and disconnect the 1 ½ hex union on
the supply line (6).
5. Remove the mounting bolts (7), lock washers (8), flat washers (9) and the worm clamp (10) from the saddle (11),
while holding the pump (1) to the mounting plate (12) on the floor. Retain the hardware.
6. Remove the 1 1/2 straight pipe section (13) from the pump inlet port (14). Retain the pipe section.
7. Remove the 1 pipe stem (15) with the attached pipe section from the priming and outlet port (16).