TM 10-3510-224-13&P
0034 00
DIRECT SUPPORT MAINTENANCE
CONTAINERIZED SELF SERVICE LAUNDRY (CSSL)
NSN 3510-01-485-0457
PRESSURE TANK
REPLACE
INITIAL SETUP:
Equipment Condition
CSSL not in operation
Materials/Parts
Solder, Lead Free (WP70, Table 1, Item 4)
Wiping Rags (WP 0070, Table 1, Item 1)
Tape, Antiseize (WP 0070, Table 1, Item 3)
Tools and Special Tools
Tool Kit, Org. Maintenance, Common No. 1
(WP 0042, Table 2, Item 2)
Personnel Required
Two
REPLACE
1. Before replacing the pressure tank (1), disconnect the freshwater hose from the freshwater input panel.
2. Connect a garden hose to the hose fitting (2) at the end of the freshwater line (3).
3. Open the freshwater pump drain line ball valve (4). Let the freshwater line drain.
The pressure tank is heavy. To avoid injuries, two persons are required to lift the
tank.
WARNING
4. To remove the pressure tank (1) disconnect the water inlet line at the union fitting (5). Remove four hex cap
screws, lock washers, and flat washers (6) from the mounting plate (7). Retain the hardware.
5. Lift the pressure tank up off the mounting plate (7).
6. To install the pressure tank (1), secure it to the mounting plate (7) with the four retained hex cap screws, lock
washers, and flat washers.
7. Connect the water inlet line at the union fitting (5).
8. Close the freshwater pump drain line ball valve (4).
9. Disconnect the garden hose from the hose fitting (2).
10. Connect the freshwater hose to the freshwater input panel.
0034 00-1