Table 1. Plumbing Troubleshooting Procedure for Containerized Batch Laundry Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Ensure CBL is set up IAW TM
Check valve setup.
4. Reuse Feed Tank overflows
10-3510-226-10. If in Minimum
Reuse mode, throttle valve V-16.
Disassemble and clean actuator
Inspect Actuator A-3 (Figure 6,
as necessary. Test the actuator
Item 1) and Actuator A-4 (Figure
IAW procedures given in WP
6, Item 2) for normal operation.
WARNING
Clear internal obstructions.
Remove tank and inspect interior
Always use safety equipment
for obstructions.
while
maintaining
graywater
handling equipment. Failure to
If further corrective action is
observe safety precautions may
required, notify direct support
result in serious illness or death
maintenance.
to personnel.