TM 10-3510-226-23
0007 00
Table 1. Plumbing Troubleshooting Procedure for Containerized Batch Laundry Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Ensure CBL is set up IAW TM
Check valve setup.
2. WTS hold tank overflows
10-3510-226-10.
Adjust valve V-15 (Figure 2,
Item 1) to restrict flow.
Ensure pump P-3 is ON at the
Check Pump P-3 (Figure 3, Item
PLC and the circuit breaker
2) for normal operation.
WARNING
panel. Test and maintain Pump
P-3 IAW procedures given in
Always use safety equipment
while maintaining graywater
handling equipment. Failure
Clean and maintain level sensor
to observe safety precautions Check level sensor (Figure 3, Item
IAW procedures given in WP
may result in serious illness or 3).
death to personnel.
Clear internal obstructions.
Remove tank IAW the "Replace"
inspect interior for obstructions.
If further corrective action is
required, notify direct support
maintenance.
1
Figure 2. WTS Hold Tank Overflows.