TM 10-3510-226-23
0007 00
Table 1. Plumbing Troubleshooting Procedure for Containerized Batch Laundry Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Ensure CBL is set up IAW TM
Check valve setup.
3. Nanofilter Feed Tank
10-3510-226-10.
overflows
Ensure actuator valve A-1 is not
Check actuator valve A-1 (Figure
locked in the open position.
4, Item 1).
maintenance procedures.
Ensure pump P-4 is ON at the
Check Pump P-4 (Figure 5, Item
WARNING
PLC and the circuit breaker
2) for normal operation.
panel. Reset P-4 overload relay
Always use safety equipment
(Figure 5, Item 3). Test and
while maintaining graywater
maintain Pump P-4 IAW
handling equipment. Failure
to observe safety precautions
may result in serious illness
or death to personnel.
Clean and maintain level sensor
Check level sensor (Figure 5, Item
IAW procedures given in WP
4).
Clear internal obstructions.
Remove tank and inspect interior
for obstructions.
If further corrective action is
required, notify direct support
maintenance.
1