BOILER TROUBLESHOOTING PROCEDURES-CONTINUED
Table 1. Boiler Troubleshooting Procedures for Containerized Batch Laundry Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7. Boiler Low Glycol
Alarm
WARNING
Antifreeze used in the following
procedure is highly toxic. Wear
appropriate protective clothing when
handling antifreeze/glycol. If
antifreeze contacts eyes or skin,
flush the affected area immediately
with clean water and seek medical
attention.
CAUTION
Do not make substitutions for the
antifreeze. The use of antifreeze
other than the type identified in the
Expendable and Durable List may
decrease performance. Failure to
comply may shorten the life span
of the equipment.
Shut boiler down immediately, and
Refill coolant reservoir with
inspect coolant reservoir (Figure 7,
ethylene glycol solution IAW TM
Item 1).
10-3510-226-10, and inspect for
leaks.
If further corrective action is
required, notify direct support
maintenance.
1
Figure 7. Boiler Low Water Alarm.