TM 10-3510-226-23
0011 00
BOILER TROUBLESHOOTING PROCEDURES-CONTINUED
Table 1. Boiler Troubleshooting Procedures for Containerized Batch Laundry Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. Boiler operating,
Check mixing valve (Figure 5, Item 1)
Adjust mixing valve IAW TM 10-
doesn't heat reuse water
setting.
Check mixing valve (Figure 5, Item 1)
Replace mixing valve IAW WP
for obstructions and malfunctions.
Check heat exchanger (Figure 5, Item
If there are obstructions, notify
2) for obstructions.
direct support maintenance.
If further corrective action is
required, notify direct support
maintenance.
2
1
Figure 5. Boiler Operating, doesn't Heat Reuse Water.
Change 1