TM 10-3510-226-23
0011 00
BOILER TROUBLESHOOTING PROCEDURES-CONTINUED
Table 1. Boiler Troubleshooting Procedures for Containerized Batch Laundry Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Provide sufficient fuel of the
8. Boiler Burner Cutout
Check fuel source (Figure 8, Item 1)
correct type (JP-8, DF-1 or DF-
Alarm
and supply; check hoses; if using 55
2).
gallon drum, ensure pickup extension
is connected.
If fuel stream is solid, with no air
spitting, go to remove nozzle
00 (Figure 8, Item 2) in
order to
verify
assembly under the Test or
fuel delivery to burner.
Inspection column on this page.
Clean strainer. Refer to WP
Inspect burner fuel pump strainer
(Figure 8, Item 3).
Refer to
WP 0068
Replace fuel filter element.
Ensure fuel filter (Figure 8, Item 4) is
Replace nozzle. Refer to WP
necessary.
Adjust or replace electrodes as
Remove nozzle assembly and inspect
electrodes (Figure 8, Item 5). Refer
Clean or replace CAD cell IAW
Check CAD cell (Figure 8, Item 6) for
soot on lens.
Replace inoperative transformer.
as necessary.
Check exhaust gas sensor (air switch)
gas sensor (air switch) IAW WP
Replace inoperative draft
Check draft inducer fan (Figure 8,
If further corrective action is
required, notify direct support
maintenance.
Change 1
0011 00-12