TM 10-3510-226-23
0023 00
TEST-CONTINUED
4. Remove screws retaining receptacle cover (Figure 1, Item 3) and remove cover.
5. Remove screws retaining receptacle (Figure 1, Item 1) to box (Figure 1, Item 4) and remove
receptacle.
6. Tag and disconnect wiring from receptacle (Figure 1, Item 1).
7. Use an ohmmeter to test for zero resistance between receptacle inlet (Figure 1, Item 2) and
corresponding terminal.
8. Use an ohmmeter to test for infinite resistance between each power inlet (Figure 1, Item 2).
9. Use an ohmmeter to test for infinite resistance between each power inlet (Figure 1, Item 2) and
ground.
10. Connect wiring to receptacle (Figure 1, Item 1) as tagged.
11. Install receptacle (Figure 1, Item 1) into box (Figure 1, Item 4) and retain with screws.
12. Install receptacle cover (Figure 1, Item 3) and retain with screws.
13. Switch circuit breaker ON and monitor for normal operation.