TM 10-3510-226-23
0036 00
REPLACE-CONTINUED
WARNING
Always discharge the pump motor capacitor before attempting any maintenance
procedures. Serious injury or death to personnel can result from electrocution if proper
safety precautions are not observed.
NOTE
It may be necessary to dismount the pump motor capacitor in order to access the shaft.
10. Tag and disconnect wiring from pump motor (Figure 13, Item 25), and remove conduit elbow (Figure
13, Item 26).
11. Install conduit elbow (Figure 13, Item 26) onto replacement pump motor (Figure 13, Item 25), and
connect wiring to motor as tagged.
12. Place a wrench on the flats of the shaft (Figure 13, Item 19) of inoperative motor.
25
19
26
Figure 13. Replace the Pump Motor.
0036 00-22