TM 10-3510-226-23
0036 00
REPLACE-CONTINUED
20. Install mounting strap (Figure 16, Item 27) and retain with nuts and bolts.
21. Apply pipe sealant to threads of suction fittings (Figure 16, Item 30) and install as an assembly.
Ensure fittings are aligned correctly.
22. Apply pipe sealant to threads of pump drain fittings (Figure 16, Item 29) and install as an assembly.
Ensure fittings are aligned correctly.
23. Apply pipe sealant to threads of discharge fittings, including pressure relief valve (Figure 16, Item 6),
and install as an assembly. Ensure fittings are aligned correctly.
24. Install pressure switch tubing (Figure 16, Item 16) and retain with compression nut.
25. Install suction hose (Figure 16, Item 15) and retain with hose clamp.
26. Install pump drain hose (Figure 16, Item 14) and retain with hose clamp.
27. Install pump pressure relief valve hose (Figure 16, Item 5) and retain with hose clamp.
28. Install pump discharge hose (Figure 16, Item 13) and retain with hose clamp.
29. Remove pump end cover (Figure 16, Item 18) from replacement motor.
30. Install pump motor conduit (Figure 16, Item 28) onto replacement motor and retain with locknut.
31. Connect pump motor wiring as tagged.
32. Install pump end cover (Figure 16, Item 18) and retain with screws.
33. Install insulation and heat trace.
34. Operate IAW procedures given in TM 10-3510-226-10 and monitor for normal operation.
0036 00-27