20. Install the pressure switch tubing (Figure 15, Item 16) onto the pump casing (Figure 15, Item 17)
and retain with compression nut.
21. Install the pump suction hose (Figure 15, Item 15) onto the hose barb and retain with hose clamp.
22. Install the pressure relief valve hose (Figure 15, Item 5) and retain with hose clamp.
23. Install the discharge hose (Figure 15, Item 13) and retain with hose clamp.
24. Install the motor mounting strap (Figure 15, Item 27) and retain with screw and nuts.
25. Install heat trace, and recover pump with insulation.
26. Close pump drain valve (Figure 15, Item 24). Operate IAW procedures given in TM 10-3510-226-10
and monitor for normal operation.