TM 10-3510-226-23
0039 00
UNIT MAINTENANCE
CONTAINERIZED BATCH LAUNDRY
NANOFILTERS
REPLACE
INITIAL SETUP
Tools
Personnel Required
Tool Kit, General Mechanics: Automotive (WP
Quartermaster and Chemical Equipment Repairer 63J
(1)
Materials/Parts
Equipment Condition
None Required
CBL set up and operating in no reuse mode only.
Pump P-4 OFF at PLC.
REPLACE
WARNING
Avoid eye, skin, and clothing contact with graywater and equipment that handles
graywater. Graywater is to be considered hazardous at all times. Full protection in the
form of rubber gloves, apron, face shield, and safety glasses should be used when
performing any type of maintenance that involves graywater. Remove any contaminated
clothing. If graywater contacts eyes or skin, flush with clean water and seek immediate
medical attention. Failure to wear proper protective clothing and equipment may result in
serious illness.
NOTE
Spent cartridge filters need to be disposed in accordance with local, state, and federal
requirements. Contact your local authorities (i.e. Facility Environmental Office) to ensure
that you are following proper disposal procedures before proceeding with nanofilter
replacement.
NOTE
Replace nanofilter cartridges as a set.
Replace Nanofilter Cartridges
1. Open nanofilter drain valves (Figure 1, Item 1) and allow to drain approximately 15 minutes.