Replace the Reuse Water Temperature Gauge
1. Drain tank.
2. Unscrew gauge (Figure 4, Item 12) from tank.
3. Apply pipe sealant or antisieze tape to threads of replacement gauge (Figure 4, Item 12).
4. Install replacement gauge (Figure 4, Item 12), ensuring the gauge is both tight and correctly oriented.
5. Monitor for leaks and normal operation.