TM 10-3510-226-23
0042 00
REPLACE-CONTINUED
Replace the Door Lock Solenoid
WARNING
Ensure that all electrical power is shut off and disconnected before proceeding. The
circuit breaker box should be locked by personnel following this procedure. Serious
injury or death can result from electrocution if proper safety precautions are not observed.
NOTE
This switch is normally open (NO).
2. Cut the wire ties (Figure 10, Item 1) retaining switch wiring to the washer frame. There may be one
or two wire ties.
3. Pull down on release (Figure 10, Item 6) and then open washer door.
4. Remove screws retaining door strike assembly (Figure 10, Item 2) and remove door strike assembly.
5. Tag and disconnect wiring from solenoid (Figure 10, Item 7).
6. Remove screws retaining solenoid (Figure 10, Item 7) to door strike assembly (Figure 10, Item 2)
and remove solenoid.
7. Install replacement solenoid (Figure 10, Item 7) onto door strike assembly (Figure 10, Item 2) and
retain with screws.
8. Connect wiring to replacement solenoid (Figure 10, Item 7) as tagged.
9. Install door strike assembly (Figure 10, Item 2) and retain with screws.
10. Retain wiring with wire tie (Figure 10, Item 1).
12. Close washer door, and operate IAW procedures given in TM 10-3510-226-10.
0042 00-17