TM 10-3510-226-23
0057 00
UNIT MAINTENANCE
CONTAINERIZED BATCH LAUNDRY
FITTINGS, WASHER QD
REPLACE
INITIAL SETUP
Tools
Personnel Required
Tool Kit, General Mechanics: Automotive (WP
Quartermaster and Chemical Equipment Repairer 63J
(2)
Materials/Parts
Equipment Condition
None Required
CBL set up
REPLACE
Replace the Washer QD Fittings
1. Disconnect washer power cord and water service to CBL.
2. Relieve water pressure from system by switching the P-1 pump off at circuit breaker No. 7 and 9,
closing water supply valve V-57, and opening the water spigot.
3. Disconnect QD fitting (Figure 1, Item 1).
4. Secure the attached piping with one pipe wrench, and use a second pipe wrench to remove the male
half of the QD fitting (Figure 1, Item 1) from the washer.
5. Secure the attached piping with one pipe wrench, and use a second pipe wrench to install the
replacement male half of the QD fitting (Figure 1, Item 1) onto the washer.
6. Loosen the hose clamp on the female half of the QD fitting (Figure 1, Item 1), and remove the female
half of the QD fitting from the hose.
7. Install the replacement female half of the QD fitting (Figure 1, Item 1) onto the hose, and tighten the
hose clamp to secure. Connect QD fitting.
8. Restore water service to CBL and check for leakage.
9. Connect washer power cord and monitor for normal operation.