TM 10-4510-201-14
OPERATOR'S MAINTENANCE INSTRUCTIONS
Section I. BASIC ISSUE ITEMS
Equipment and technical manuals issued with or
authorized for the bath unit are listed in the Basic
Section II. LUBRICATION INSTRUCTIONS
The bath unit requires no lubrication except for the
CAUTION
auxiliary equipment-the generator set. The lubrication
When firing fuel burner with
instructions for the generator sets are found in TM 5-
gasoline, mix one quart OE-30 oil
with each five gallons of gasoline.
motors on the water heater and on the water pump are
This mixture will provide internal
factory-sealed and require no lubrication.
lubrication for the fuel pump. To
assure proper mixture ratio, pour
gasoline into the oil.
Section III. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
operation of the bath unit shall be noted for future
correction, to be made as soon as operation has ceased.
To insure that the bath unit is ready for operation at all
Stop operation immediately if a deficiency is noticed
times, it must be inspected systematically so that
which would damage the equipment if operation were
defects may be discovered and corrected before they
continued. All deficiencies and shortcomings, together
result in serious damage or failure. The necessary
with the corrective action taken, will be recorded on DA
preventive maintenance services to be performed on
Form 2404 (Equipment Inspection and Maintenance
Worksheet) at the earliest possible opportunity.
The item numbers indicate the sequence of minimum
inspection requirements. Defects discovered during