TM 10-4510-207-14
Table 4-1. Unit Preventive Maintenance Checks and Services for SHOWER-1
Location
Not Fully Mission
Procedure
Interval
Item
Item to be
Capable If:
No.
Checked or
Serviced
Shower Facility
Shower Head
Nozzle is clogged or
Weekly
1
Manifold
valve does not work
of each nozzle valve as well as the nozzle spray. If
Assembly
smoothly.
spray is not even, clean the nozzle. If the nozzle
Pump Assembly
Damaged of leaking
Weekly
Check pump assembly for leak or damage. Repair as
2
Pump Assembly
enough to interfere with
necessary.
operation.
Interconnection
System
Supply hose is damaged
Weekly
Shut down shower and relieve system pressure
3
Supply Hoses
time and check for obstructions. Clean as necessary
and replace if damaged.
Weekly
4
Drain Hoses
Drain hose is damaged
drain hose one at a time and check for obstructions.
or obstructed.
Clean as necessary and replace if damaged.
Weekly
Check all hoses and fittings for damage, leaking, or
5
Hoses and Fittings
Hose is damaged, loose,
loose connection. Replace if damages, repair leaks as
or leaking enough to
necessary, tighten loose connections.
interfere with operation.
Weekly
Check all power cables for damage or loose
6
Power Cable
Power cable is damaged
connection. Replace if damaged and tighten any loose
Assembly
or connection is loose.
connections.
4-4