TM 10-4510-208-13&P
OPERATOR MAINTENANCE
CONTAINERIZED SHOWER & SHOWER, ENCLOSED UNIT, SYSTEM
INTERIOR LIGHTING TROUBLESHOOTING PROCEDURES
Table 1. Interior Lighting Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. LIGHTS INOPERATIVE
WARNING
Lethal voltage is present when
light set is connected to power
source.
Step 1. If all lights are
Ensure an external power source
inoperative, check external power
is connected to the power input
and cable connection to the
power input panel.
Step 2. Check interior light or
Reset GFCI or circuit breaker by
convenience outlet GFCI and
turning switch OFF, then ON.
circuit breaker (Containerized
(Containerized Shower only), or
Shower only), or shave stand
(re)connect extension cord.
lights extension cord connection.
Step 3. If only individual light(s)
Replace bulbs on all individual,
are inoperative, check the bulbs
inoperative lights. Refer to WP
for proper seating.
If condition persists, notify Unit
Maintenance.
Shave Stand
Light
Fluorescent
Light
0014 00-1/(2-Blank)