TM 10-4510-208-13&P
OPERATOR MAINTENANCE
CONTAINERIZED SHOWER & SHOWER, ENCLOSED UNIT, SYSTEM
WATER TROUBLESHOOTING PROCEDURES
Table 1. Water Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Check to ensure water feed is
1. NO WATER TO SHOWER
Step 1. Ensure water service feed
connected properly. Refer to WP
is connected to water source and
0005 00 or 0006 00, as
water is available at the source.
applicable.
Check all valves to make sure they
are open.
Verify pump (Containerized
Step 2. Ensure 30 gpm water
Shower only) and M-80 water
(Containerized Shower only) pump
heater are turned ON and
and M-80 water heater are
reconnect water hoses as
operating properly, and water hose
necessary.
connections are tight.
Step 3. Ensure hot and cold water
Open hot and cold water shutoff
shutoff valves are in the ON
valves.
position.
If problem continues, notify unit
maintenance.
Water
Water
Tank
Pump
Water
Heater
Water
Service
Panel
Hot and Cold
Water Shutoff
Valves
(shown OFF)
CONTAINERIZED SHOWER
0018 00-1