TM 10-4510-208-13&P
OPERATOR MAINTENANCE
CONTAINERIZED SHOWER & SHOWER, ENCLOSED UNIT, SYSTEM
SPACE HEATER TROUBLESHOOTING PROCEDURES
Table 1. Space Heater Troubleshooting Procedures (Containerized Shower Only).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. SPACE HEATER
INOPERATIVE
WARNING
NOTE
Lethal voltage is present when
the heater is connected to power
location of circuit breakers.
source.
Step 1. Check that thermostat is
Turn thermostat ON wait at
turned ON.
least five minutes for heater to
come on.
Step 2. Check space heater
Reset circuit breaker by switching
circuit breaker.
breaker OFF, then ON.
Step 3. Check main circuit
Reset circuit breaker by switching
breaker.
breaker OFF, then ON.
If condition persists, notify Unit
Maintenance.
Space
Heater
Circuit
Breakers
Thermostat
Power
Control
Input
Panel
60A
Cable
0015 00-1/(2 Blank)