TM 10-4510-209-13&P
OPERATOR MAINTENANCE
CONTAINERIZED LATRINE (CL)
CONTAINERIZED LATRINE SYSTEM (CLS)
FLUORESCENT LIGHT BULBS
REPLACE
INITIAL SETUP
Tools
Personnel Required
One (1)
Materials/Parts
Equipment Condition
Leather Gloves
CL/CLS set up and operating.
Circuit Breaker OFF.
REPLACE
Replace Fluorescent Light Bulbs (Containerized Latrine (CL))
WARNING
Power must be shut down at the light switch and circuit breaker (#2) before replacing
fluorescent lights. Failure to follow this warning could result in serious injury or death to
personnel by electrocution. Always secure and tag circuit breakers and switches OFF
before attempting any electrical repairs, even minor tasks such as replacing a bulb.
Remember that the latrine is a wet environment, and capable of posing a shock hazard
even when personnel are not in direct contact with metal parts.
WARNING
Fluorescent bulbs can shatter during changing. Gloves and eye protection are required.
Serious injury could result to personnel if safety precautions are not observed.
NOTE
A step aid may be required to change fluorescent bulb.
1. Remove the bulb retaining clips (1), if fitted (two per bulb).
2. Support fluorescent bulb (2) firmly and twist to remove.
3. Remove transparent bulb sleeve (3) from bulb (2) and install onto replacement bulb.
0020 00-1