TM 10-4510-209-13&P
0067 00
7. Unscrew the power cord strain relief locknut (9), and remove the power cord (1) from the pressure
switch (7).
8. Disconnect the pressure switch hose (10) by unscrewing the barb fitting on the pipe Tee (11).
9. Remove cover from fresh water pump motor junction box (12).
10. Tag and disconnect wiring from pump motor (13).
9
8
1
7
6
10
11
13
12
11. Support the pump (4), loosen the locknut (14), and unscrew the conduit elbow (15) from the pump
motor (13). Leave the conduit and pressure switch (7) attached as an assembly.
12. Remove the bolts (16) holding the pump support bracket onto the pump motor.
0067 00-4