24. Install the pump base plate (22) onto the replacement pump (4), and retain with screws, washers, and
nuts.
25. Apply pipe sealant to the threads of the pipe Tee nipple. If pipe sealant is not available, wrap three to
five turns of antisieze tape clockwise around the threads.
26. Install the pipe Tee (25) with pressure gauge (24) as an assembly onto the replacement pump (4).
Ensure that the pressure gauge is aligned correctly.
27. Apply pipe sealant to the threads of the pipe Tee nipple for the brass fitting assembly. If pipe sealant
is not available, wrap three to five turns of antisieze tape around the threads.
28. Install the pipe Tees with brass fitting onto the replacement pump. Ensure the Tees are aligned
correctly.
29. Remove the cover from the junction box (12) on the replacement pump (4), and remove the knockout
plug from the junction box.
30. Screw the pressure switch conduit elbow (15) with pressure switch (7) and bracket as an assembly
onto the junction box (12).
31. Install the pump (4) with pump base plate (22) onto the pump mount (23).
32. Place one hose clamps on each piece of flex hose and connect flex hose to appropriate piece of pipe.
Secure in place by tightening hose clamp.
33. Retain the pump mount (23) with nuts and tighten.
34. Connect the wiring from pressure switch (7) to the motor (13) as tagged.
35. Install the cover to the junction box (12), and secure with screws.
36. Install the pressure switch hose (10) onto the pipe Tee (11).
37. Install the drain plug (5), as well as any remaining plugs.
38. Install the strain relief conduit locknut (9) into the pressure switch (7), and secure.
39. Connect the power cord (1) to the pressure switch (7) as tagged.
40. Install the pressure switch cover (6).
41. Install the pump cover (3).
42. Prime pump, reconnect power, and operate in accordance with procedures outline in WP 0009 00.
43. Monitor for normal operation.
0067 00-7