TM 10-4510-209-13&P
0067 00
18
19
21
19
20
18
19
18
17
19. Remove the nuts retaining the pump base plate (22) to the pump mount (23).
CAUTION
Use caution when removing the pump. Do not damage the pressure gauge or pressure
switch when removing.
20. Remove the pump (4) and base plate (22) as an assembly from the pump mount (23).
21. Note the position of the pressure gauge (24), then remove the pipe Tee (25) and pressure gauge as
an assembly from the pump (4). Ensure the close nipple connecting the Tee to the pump comes out
with the Tee.
22. Note the position of the brass fitting, then remove the pipe Tees and brass fitting as an assembly from
the pump.
23. Remove the screws, washers, and nuts retaining the pump base plate (22) to the pump (4), and
remove the pump base plate.